How it Works
No Straight Run     
Required     
High Accuracy and     
Extended Turndown     
Models and     
Specifications     
Applications
Sizing Software
 
Verabar Provides the Accuracy

The proven technology of the Verabar makes the Accelabar work. It accurately measures the flow rate within the nozzle. Its unique bullet shape, constant flow coefficient, solid-one-piece construction, non-clog design and signal stability make it the only design capable of producing the overall performance.






Verified Accuracy and Flow Coefficients

Empirical test data from independent laboratories verified an analytical model and flow coefficients as constant and independent of Reynolds Number and within ±0.75% of the predicted value over a flow turndown of 65:1 (see actual test). This eliminates the need for calibration.